AIR CONDITIONING (A/C)
DESCRIPTION
General
The Air Conditioning (A/C) system provides cooled air for the occupants
of the car. The system is sealed and filled with refrigerant R134a.
The compressor, driven by the alternator drive belt, pumps low pressure
refrigerant vapour from the evaporator to the condenser. As the refrigerant
passes through the condenser, it is cooled by air passing over the outer
fins. The vapour reverts to its liquid state as it is cooled. Air flow
over the cooling fins is assisted by the cooling fan and the condenser
fan. From the condenser, the refrigerant passes to the receiver-drier
which acts as a reservoir and also removes any moisture from the refrigerant.
High pressure liquid refrigerant passes through the thermostatic expansion
valve which converts the refrigerant to a low pressure spray as it enters
the evaporator. The change in pressure causes the liquid to change to
a vapour and as it does so, heat is absorbed from the surrounding air.
Air is blown over the evaporator matrix and directed into the passenger
compartment. The refrigerant vapour in the evaporator returns to the compressor
and continues the cycle. The system contains a number of safety features
which guard against mechanical damage. If the refrigerant pressure is
too high or too low, the evaporator matrix is too cold, the compressor
becomes too hot or the engine coolant temperature becomes too high, the
compressor drive is disengaged.
System operation is controlled by the A/C switch on the centre console
and the Engine Control Module (ECM). The system only operates when one
of the four blower speeds is selected and the engine is running.
OPERATION
Power supplies
Fuse 5 (C0601) and fuse 6 (C0572) of the under bonnet fuse box provide
the A/C relay pack (C0172) with permanent feeds on NW and N wires respectively.
The A/C relay pack contains relays for the compressor clutch, cooling
fan and condenser fan.
Fusible link 4 (C0570) and fusible link 5 (C0573) of the under bonnet
fuse box provide the ignition switch (C0028) with permanent feeds on NP
and NW wires respectively. When the ignition switch is in position II,
feeds are connected from the ignition switch to:
l Fuse 15 (C0099) of the passenger compartment fuse box on a Y wire. From
fuse 15 (C0585), the feed is connected to the A/C relay pack (C0173),
A/C switch pack
(C0275), fresh/ recirculated air switch (C0750) and fresh/ recirculated
air mode motor (C0413) on LGS wires.
l Fuse 24 (C0595) of the satellite fuse box on a WLG wire. From fuse 24
(C0595), the feed is connected to the blower motor (C0056) on a LGP wire
and from the blower motor (C0056) to the blower motor switch (C0058) by
a SB wire. When the blower is selected to positions 1 to 4, the feed is
supplied from the blower switch (C0058) to the A/C switch pack (C0275)
on a SW wire.
A/C request
When the A/C switch is pressed, while one of the four blower speeds is
selected, SK wires connect the power feed from the A/C switch pack (C0275)
to the A/C thermostat (C0422) and from the A/C thermostat (C0423) to the
trinary switch (C0279). Provided the high and low temperature switches
are closed, the trinary switch (C0279) then supplies the power feed to
the ECM (C0159 on MPi MEMS 1.9 and VVC MEMS 2J models, C0634 on MPi MEMS
3 models) on a UR wire. With A/C selected on, the tell tale illumination
LED in the A/C switch pack (C0275) is earthed on the B wire, connected
to an earth header (C0017), and illuminates.
When the ECM receives an A/C request, it energises the appropriate relays
in the A/C relay pack to operate the compressor, cooling fan and condenser
fan.
The high and low switches in the trinary switch guard against extremes
of pressure in the refrigerant system. If refrigerant system pressure
reaches either of the limits, the related switch opens and disconnects
the A/C request to the ECM. The air temperature sensor detects evaporator
matrix temperature and, if the temperature is less than 2 °C (36 °F),
opens and disconnects the A/C request to the ECM.
Compressor
To operate the compressor, the ECM earths the UB wire between the ECM
(C0159 on MPi MEMS 1.9 and VVC MEMS 2J models, C0634 on MPi MEMS 3 models)
and the compressor clutch relay in the A/C relay pack (C0173). The energised
compressor clutch relay connects the power feed from fuse 5 in the under
bonnet fuse box to the R wire between the A/C relay pack (C0172) and the
A/C compressor clutch (C0127). The A/C compressor clutch is earthed through
the compressor fixings and energises to transmit drive to the compressor.
Cooling and condenser fans
The ECM operates the two fans together at one of two speeds. Low speed
is achieved by connecting the fans in series and high speed is achieved
by connecting the fans in parallel.
The fans operate at low speed when either the compressor clutch is engaged
or the engine coolant temperature is between 92 and 99 °C (198 and
210 °F). The fans operate at high speed when either the engine temperature
is in excess of 107 °C (225 °F) or the medium pressure switch
in the trinary switch detects a system pressure in excess of 18 bar (261
lbf.in 2 ). When refrigerant system pressure exceeds 18 bar (261 lbf.in
2 ), the medium pressure switch closes and connects the UG wire, between
the ECM (C0159 on MPi MEMS 1.9 and VVC MEMS 2J models, C0634 on MPi MEMS
3 models) and the trinary switch (C0279), to earth on the B wire between
the trinary switch (C0279) and the earth point (C0564 on LHD) or earth
header (C0017 on RHD).
On receipt of an A/C request, the ECM (C0159 on MPi MEMS 1.9 and VVC MEMS
2J models, C0634 on MPi MEMS 3 models) earths the US wire from the A/C
relay pack (C0173) to energise cooling fan relay 2. The energised cooling
fan relay 2 connects the feed from fuse 6 of the under bonnet fuse box
to the PS wire between the A/C relay box (C0172)
and the cooling fan motor (C0005). The feed passes through the cooling
fan motor (C0005) to cooling fan relay 1 in the A/C relay pack (C0172)
on the US wire, then from cooling fan relay 1 to the condenser fan relay.
The condenser fan relay connects the feed to the SU wire between the A/C
relay pack and (C0172) and the condenser fan (C0280). The condenser fan
(C0280) is earthed on a B wire connected to an earth header (C0017). With
the fans connected in series, they run at slow speed.
If engine temperature or system pressure increase to their respective
switching point, the ECM (C0159 on MPi MEMS 1.9 and VVC MEMS 2J models,
C0634 on MPi MEMS 3 models) earths the UY wire to energise cooling fan
relay 1 and the condenser fan relay in the A/C relay pack (C0173). The
energised cooling fan relay 1 switches the feed from the cooling fan motor
to earth on the B wire between the A/C switch pack (C0172) and the earth
point (C0564 on LHD) or earth header (C0017 on RHD). The energised condenser
fan relay switches a feed from fuse 5 in the under bonnet fuse box to
the SU wire between the A/C relay pack (C0172) and the condenser fan (C0280).
With the fans connected in parallel, they run at high speed.
Recirculated air
With the fresh/ recirculated air switch in the fresh air (off) position,
current flows from the fresh/ recirculated air mode motor (C0413) to the
fresh/ recirculated air switch (C0750) on the Y wire and to earth on a
B wire between the fresh/ recirculated air switch (C0750) and an earth
header (C0017). With the fresh/ recirculated air switch in the recirculated
air (on) position, current flows from the fresh/ recirculated air mode
motor (C0413) to the fresh/ recirculated air switch (C0750) on the K wire
and to earth on the B wire; the tell tale illumination in the fresh/ recirculated
air switch is also earthed on the B wire and illuminates to indicate the
position on the fresh/ recirculated air mode motor.
|